Mine Neutralization Exercise (MINEX) Sound Measurement Trial

Authors: Soloway and Dahl Year published: 2014 File size: 1,460.29 KB

About

In September 2012 a team from the University of Washington, joined by personnel from Naval Facilities Engineering Command (NAVFAC) Atlantic and HDR, Inc., conducted a set of measurements of the underwater sound generated by sub-surface explosions from mine warfare exercise (MINEX) activities. In total five tests were conducted with explosive charges ranging from 0.1 to 6.0 kilograms of TNT-equivalent. The primary metrics used to quantify the sound from underwater explosions are the peak pressure generated by the explosion and the sound exposure level (𝑆𝐸𝐿). Three key findings emerged from this study: 1. The measured peak pressures were compared to the semi-empirical equation involving the scaling parameter R/W1/3, or the range from the explosive source divided by weight to the one-third power, where π‘ƒπ‘π‘’π‘Žπ‘˜ is the peak pressure in pascals (Pa), 𝑅 is the measurement range in meters, and π‘Š is the charge weight in kilograms of TNT. π‘ƒπ‘π‘’π‘Žπ‘˜=52.4Γ—106τ€΅¬π‘…π‘Š1/3τ€΅°βˆ’1.13 The scaling parameter is also referred to as scaled range and measurements were found to be in very good agreement with the peak pressure equation over values of scaled range going from 200 to 2,000, as expressed in meter-kilograms-sec units. 2. Using the 90 percent energy approach, the sound exposure level (SEL) for the five tests were 174–190.4 𝑑𝐡 π‘Ÿπ‘’ 1πœ‡π‘ƒπ‘Ž2𝑠. These results were found to be highly dependent on charge weight and range from the source, and it was determined that SEL was also well predicted using a modification of scaled range that involves an additional factor of π‘Š1/3, which arises from a semi-empirical equation for the energy flux density. The SEL is a measure of the total acoustic energy received by an organism, and is a common metric used in environmental acoustics as it allows for the comparison of sounds of varying duration. 3. Finally, measurements of Scholte interface waves were recorded during two of the tests. The extremely low-frequency (less than 10 Hertz) Scholte wave necessitated a precise correction for the effect of resistance and capacitance in the hydrophone and receiving network. The Scholte waves arrived between 1 and 4 s after the direct water arrival. Based on these arrival times, the shear speed in the sediment was estimated to be in the range of 100–370 π‘š/𝑠. Preliminary modeling using the wavenumber integration approach confirmed that the measured signal was a Scholte wave, and the estimate of sediment shear speed is a reasonable estimate. The Scholte wave is of relatively high amplitude for this frequency range (2-5 Hertz).

View document